Fire Suppression System for the Crew Compartment of the PPO ВV Vehicle

PPO ВV

NSN 4210 61 019 1015 (2 cylinders)
NSN 4210 61 019 1017 (4 cylinders)
ТУ У 26.3-22362867-093:2025

The fire suppression system detects fire in the crew compartment of the vehicle and generates electrical signals that control the components of fire suppression equipment:

  • Audio and light alarms in case of fire in the crew compartment
  • Firefighting cyclogram

The system’s devices are resistant to high shock and vibration and are suited for operation under rough conditions.

To obtain information about our products during the preparation of tender or contractual documentation, please contact our representatives via the provided contacts. We continuously improve our products and expand their functionality in line with market needs by applying the latest technologies, modern components, and materials. Therefore, specifications, descriptions, and configurations are subject to change without prior notice.

Features
  • Operating modes – 2 (automatic, manual)
  • Integrated self-monitoring system
  • Optical sensor serviceability control
  • Pressure control in the cylinders
  • Issuance of audio and light fire signal
  • Delivery of fire extinguishing cyclogram after receiving a fire signal from optical sensors
  • Automatic or manual detonation of pyro cartridges for supply of fire-extinguishing mixture
  • High shock and vibration resistance of the system components
  • Waterproof
  • Built-in operation control with and without commands issued to the actuators
  • Adapted to work in harsh operating conditions
  • Data transfer to the on-board computer

Purpose Of Use

  • Detection of fire in the crew compartment of the vehicle and its extinguishing in automatic or manual modes with light and audio signaling about the operating modes of this system

Delivery Kit

  • BP PPO console unit of the fire-fighting equipment system – 1 pcs
  • Optical sensor OD1U – from 1 to 5 pcs (depending on a vehicle)
  • cylinders with the extinguishing agent HFC 227 or АЛ-5-1-12 – from 1 to 4 pcs (depending on a vehicle)
  • logbook
  • installation kit
  • package

Specifications

Power supply voltage
22.5 ... 28.5 V
Power consumption in standby mode - less than
5 W
Operating temperature range
-40 ... +60 °С
Time of full extinguishing from the moment of fire detection is less than
250 ms