Fire Suppression System for the Engine Compartment of the PPO MV Vehicle

PPO MV

NSN 4210 61 019 1016 (2 cylinders)
NSN 4210 61 019 1018 (4 cylinders)
ТУ У 26.3-22362867-092:2025

The PPO MV fire suppression system detects fire in the engine compartment of a special-purpose vehicle and generates еlectrical signals that control the components of fire protection equipment:

  • Audio and light alarms in case of а fire in the engine compartment,
  • Cyclogram of firefighting.

The system’s devices are resistant to high shock and vibration and are suited for operation under rough conditions.

To obtain information about our products during the preparation of tender or contractual documentation, please contact our representatives via the provided contacts. We continuously improve our products and expand their functionality in line with market needs by applying the latest technologies, modern components, and materials. Therefore, specifications, descriptions, and configurations are subject to change without prior notice.

Features
  • Operating modes – 2 (automatic, manual)
  • Integrated self-monitoring system with and without issuing commands to the actuators
  • Pressure control in the cylinders
  • Control of the serviceability of starting devices of fire extinguishing mechanisms (pyro cartridges)
  • Control of ten zones of the engine unit compartment
  • Delivery of the fire-extinguishing composition of the first group of cylinders to the engine unit compartment in the event of a fire
  • Temperature detector serviceability control
  • Repeated supply of the fire-extinguishing composition of the second group of cylinders to the compartment in case of repeated or incomplete elimination of the fire
  • Issuing a command to stop the engine. Execution of the fire extinguishing cyclogram after receiving the engine stop signal
  • Waterproof
  • Data transfer to the on-board computer
  • An option to produce the marine version of the equipment

Purpose Of Use

  • Detection of fire in the engine compartment of a special-purpose vehicle and its extinguishing in automatic or manual modes with light and audio signaling about the operating modes of this system

Delivery Kit

  • BP PPO console unit of the fire-fighting equipment system
  • TD-1U temperature detector – from 1 to 10 pcs
  • cylinders with the extinguishing agent Halocarbon 114В2 of BRS 2 type (Quick Release Connector) – from 1 to 4 pcs
  • installation kit
  • logbook
  • package

Specifications

Power supply voltage
22.5 ... 28.5 V
Power consumption in standby mode
5 W
Operating temperature range
-40 ... +60 °С