Multipurpose Survey Meter

MKS-UM

NSN 6665 61 016 9197
ТУ У 26.5-22362867-051:2021

MKS-UM is a full-range radiation survey device in the field environment, which measures alpha, beta, gamma and X-ray radiation. The gamma radiation dose rate is measured from the background to emergency levels. High protection rating and a hard shell allow using the device in harsh climatic and dusty conditions.

Complies with MIL-STD-810G, MIL-STD-461F standards. Complies with ІЕС 60846, ІЕС 60325 standards

To obtain information about our products during the preparation of tender or contractual documentation, please contact our representatives via the provided contacts. We continuously improve our products and expand their functionality in line with market needs by applying the latest technologies, modern components, and materials. Therefore, specifications, descriptions, and configurations are subject to change without prior notice.

Features
  • Scintillation detectors and gas discharge Geiger-Muller meters without return run of counting response
  • Possibility to measure ambient dose equivalent rate (DER) of gamma radiation with the detector which is built in the control unit
  • Automatic selection between measurement intervals and ranges
  • Audio signaling of each registered gamma-quantum, beta particle and alpha particle
  • Backlight of display and control buttons for operation in the dark
  • Rechargeable Li-lon battery charging by the built-in charger from:
    • solar panel
    • 12 V automobile battery
    • industrial network 220 V/50 Hz
  • Multilevel indication of battery discharge
  • Analog indicator of radiation intensity
  • IP56 of control unit and IP57 of detecting units
  • Logging of up to 1500 measurement results tagged to location coordinates in the non-volatile memory via USB/IrDA adapter to the PC (built-in GPS receiver)
  • Viewing of logged measurement results on the display
  • Easy to operate even if wearing personal protection – rubber gloves

Purpose Of Use

  • Measurement of ambient dose equivalent rate (DER) of gamma and X-ray radiation
  • Measurement of ambient dose equivalent (DE) of gamma and X-ray radiation
  • Measurement of beta-particles surface flux density and beta-particles surface activity
  • Measurement of alpha-particles surface flux density and alpha-particles surface activity
  • Measurement of accumulation time of gamma and X-ray radiation DE
  • Archive of measurement results tagged to location coordinates

Delivery Kit *

  • control unit
  • BDKS-01 combined detecting unit of gamma, beta radiation (BG probe)
  • BDKS-02 combined detecting unit of alpha, beta, gamma radiation (ABG probe)
  • earpiece
  • cable
  • spare parts set
  • set of operational documents (operating manual, logbook, software and USB/IrDA drives on CD-R mini)
  • tools and accessories (hoop, 2 carrying straps, telescopic tube armrest, telescopic tube, carrying case, USB/IrDA adapter, solar panel, power cable DC, hard shell, screwdriver, power supply unit with AC cord)
  • package

* The delivery kit may be completed upon customer’s request

Specifications

Specifications Of The Control Unit Of The MKS-UM Dosimeter-Radiometer
Measurement range of photon-ionizing radiation DER
10-1 … 106 μSv/h
Indication range of pulse count rate from gamma radiation detector
0 … 9 999 cps
Measurement range of photon-ionizing radiation DE
0.001 … 9 999 mSv
Main relative permissible error limit during DER measurement at 137Cs calibration with 0.95 confidence probability, where H*(10) is a dimensionless quantity, numerically equal to DER value measured in μSv/h
(15+2/H*(10)) %
Main relative permissible error limit during DE measurement at 137Cs calibration with 0.95 confidence probability
15 %
Energy range of recorded photon-ionizing radiation
0.05 … 3 MeV
Energy dependence during photon-ionizing radiation DER and DE measurement in the energy range from 0.05 MeV to 1.25 MeV, relative to 0.662 MeV energy, not more
20 ... 40 %
Measurement range of DE accumulation time
1 min … 9 999 hrs
Accuracy of DE accumulation time measurement for 24 hrs
±1 min
Operating supply voltage of the dosimeter from Li-Ion storage battery (4 500 mAh)
3.7 V
Additional relative permissible error limit during measurement caused by supply voltage deviation from the reference value in the voltage range from 3.0 V to 4.2 V, for all measured physical quantities, not more
5 %
Additional relative permissible error limit during measurement caused by deviation of environmental temperature from 20 °С in the temperature variation range from -30 to +55 °С
5 % per each 10 °С deviation from 20 °С
Operating mode setup time while the control unit is exposed to photon-ionizing radiation with DER equal to 5 µSv/h, not more
5 min
Time of continuous operation of the dosimeter powered from a fully charged, Li-Ion battery of 4 500 mAh capacity under normal climatic conditions
at gamma background up to 0.5 µSv/h when ABG/BG probes are disconnected and the display backlight and GPS-receiver are switched off, not less
1 200 hrs
at gamma background up to 0.5 µSv/h when ABG/BG probes are disconnected, the display backlight and GPS-receiver are switched on, not less
70 hrs
when ABG or BG probe is connected in the mode of any radiation type measurement, the display backlight and GPS-receiver are switched off, not less
300 hrs
when ABG or BG probe is connected in the mode of any radiation type measurement, the display backlight and GPS-receiver are switched on, not less
50 hrs
Unstable readings of the dosimeter during DER measurement for an 8-hour continuous operation, not more
5 %
Dimensions of the control unit (in hard shell with solar panel), not more
166 × 70 × 132 mm
Weight of the control unit, not more
0.7 kg
Weight of the control unit (in hard shell with solar panel), not more
1.3 kg
Specifications Of The Bdks-01 Combined Detecting Unit Of Gamma, Beta Radiation (Bg Probe)
Measurement range of photon-ionizing radiation DER
10-1 … 107 μSv/h
Indication range of pulse count rate from gamma radiation detector
0 … 9 999 cps
Main relative permissible error limit during photon-ionizing radiation DER measurement at 137Cs calibration with 0.95 confidence probability, where H*(10) is a dimensionless quantity, numerically equal to DER value measured in μSv/h
(15+2/H*(10)) %
Energy range of recorded photon-ionizing radiation
0.05 … 3 MeV
Additional relative permissible error limit during measurement of photon-ionizing radiation DER caused by deviation of environmental temperature from 20 °С in the temperature variation range from -30 to +55 °С
5 % per each 10 °С deviation from 20 °С
Operating mode setup time while the BG probe is exposed to photon-ionizing radiation with DER equal to 5 µSv/h, not more
1 min
Operating mode setup time when measuring surface beta-particles flux density and surface activity of beta-emitting radionuclides, not more
1 min
Measurement range of surface beta-particles flux density
10 … 200 000 part./(cm²·min)
Measurement range of surface activity of beta-emitting radionuclides
0.5 … 9 000 Bq/cm² for С0 source type (90Sr/90Y)
Indication range of pulse count rate from beta radiation detector
0 … 9 999 cps
Energy range of recorded beta radiation
0.3 … 3 MeV
Main relative permissible error limit during measurement of surface beta-particles flux density at 90Sr/90Y calibration with 0.95 confidence probability , where Fβ is a dimensionless quantity, numerically equal to surface beta-particles flux density value measured in part./(cm²·min)
(20+200/Fβ) %
Main relative permissible error limit during measurement of surface activity of beta-emitting radionuclides at 90Sr/90Y calibration with 0.95 confidence probability from С0 type source, where Аβ is a dimensionless quantity, numerically equal to surface activity of beta-emitting radionuclides value measured in Bq/cm²
(20+10/Аβ) %
Area of the detector’s sensitivity
1 cm²
Beta-particles recording efficiency, not less
for 14С isotope
-
for 204Tl isotope
-
for 90Sr/90Y isotope
0.25
Additional relative permissible error limit during measurement of surface beta-particles flux density and surface activity of beta-emitting radionuclides caused by variation of environmental temperature from -30 to +55 °С
5 % per each 10 °С of deviation from 20 °С
Unstable readings during measurement of all physical quantities for an 8-hour continuous operation, not more
5 %
Dimensions of the BG probe, not more
47 × 95 × 176 mm
Weight of the BG probe, not more
0.3 kg
Specifications Of The Bdks-02 Combined Detecting Unit Of Alpha, Beta, Gamma Radiation (Abg Probe)
Measurement range of photon-ionizing radiation DER
10-1 … 2·106 μSv/h
Indication range of pulse count rate from photon-ionizing radiation detector
0 … 9 999 cps
Main relative permissible error limit during measurement of photon-ionizing radiation DER at 137Cs calibration with 0.95 confidence probability, where H*(10) is a dimensionless quantity, numerically equal to DER value measured in μSv/h
(15+2/H*(10)) %
Energy range of detected photon-ionizing radiation
0.05 … 3 MeV
Additional relative permissible error limit during measurement of photon-ionizing radiation DER caused by deviation of environmental temperature from 20 °С in the temperature variation range from -30 to +55 °С
5 % per each 10 °С of deviation from 20 °С
Setup time of operating mode while the ABG Probe is exposed to photon-ionizing radiation with DER equal to 5 µSv/h, not more
1 min
Setup time of operating mode when measuring beta-particles flux density and surface activity of beta-emitting radionuclides, not more
1 min
Measurement range of surface beta-particles flux density
10 … 300 000 part./(cm²·min)
Measurement range of surface activity of beta-emitting radionuclides for С0 source type (90Sr/90Y)
0.5 … 13 500 Bq/cm²
Indication range of pulse count rate from beta radiation detector
0 … 9 999 cps
Energy range of detected beta-particles
0.15 … 3 MeV
Main relative permissible error limit during measurement of surface beta-particles flux density at 90Sr/90Y calibration with 0.95 confidence probability , where Fβ is a dimensionless quantity, numerically equal to surface beta-particles flux density value measured in part./(cm²·min)
(20+200/Fβ) %
Main relative permissible error limit during measurement of surface activity of beta-emitting radionuclides at 90Sr/90Y calibration with 0.95 confidence probability from standard source of С0 type , where Аβ is dimensionless quantity, numerically equal to surface activity of beta-emitting radionuclides value measured in Bq/cm²
(20+10/Аβ) %
Area of the detector’s sensitivity
7 cm²
Beta-particles detection efficiency, not less
for 14С isotope
-
for 204Tl isotope
-
for 90Sr/90Y isotope
0.4
Additional relative permissible error limit during measurement of surface beta-particles flux density and surface activity of beta-emitting radionuclides caused by variation of environmental temperature from -30 to +55 °С
5 % per each 10 °С of deviation from 20 °С
Measurement range of surface alpha-particles flux density
10 … 300 000 part./(cm²·min)
Measurement range of surface activity of alpha-emitting radionuclides for П9 source type (239Pu)
0.5 … 10 000 Bq/cm²
Energy range of detected alpha-particles
4 … 8 MeV
Indication range of pulse count rate from alpha radiation detector
0 … 9 999 cps
Main relative permissible error limit during measurement of surface alpha-particles flux density at 239Pu calibration with 0.95 confidence probability , where Fα is a dimensionless quantity, numerically equal to surface alpha-particles flux density value measured in part./(cm²·min)
(15+300/Fα) %
Main relative permissible error limit during measurement of surface activity of alpha-emitting radionuclides at 239Pu calibration with 0.95 confidence probability from standard source of П9 type , where Аα is a dimensionless quantity, numerically equal to surface activity of alpha-emitting radionuclides value measured in Bq/cm²
(15+15/Аα) %
Area of the detector’s sensitivity
13 cm²
Alpha-particles detection efficiency from 239Pu isotope, not less
0.06
Additional relative permissible error limit during measurement of surface alpha-particles flux density and surface activity of alpha-emitting radionuclides caused by variation of environmental temperature from -30 to +55 °С
5 % per each 10 °С of deviation from 20 °С
Setup time of operating mode when measuring alpha-particles flux density and surface activity of alpha-emitting radionuclides, not more
1 min
Unstable readings during measurement of all physical quantities during an 8-hour continuous operation, not more
5 %
Dimensions of the ABG probe, excluding the dimensions of the swivel bracket for mounting to the telescopic tube, not more
72 × 186 × 55 mm
Weight of the ABG probe, not more
0.7 kg

Other products

Ask a question

Order the product:
MKS-UM Multipurpose Survey Meter